Ballast Grid Systems
Ballast Thermal Storage Retrofit
Fixed-rate notes on salt storage bolted onto an operating plant, so a baseload machine can chase the peak price.
A nuclear plant is a machine that produces constant heat, and an electricity market pays wildly varying prices for it. Storing heat in molten salt during cheap hours and drawing it down during expensive ones is arbitrage against the plant's own inflexibility, using equipment already proven at concentrated solar plants. No nuclear license amendment is required because nothing on the nuclear side is modified.
$20,240,000 committed of $22,000,000
$18,216,000 released · 92% subscribed
- Minimum
- $500
- Target coupon
- 6.45%
- Term
- 5 yr
- Investors
- 2,961
$100 per unit
Annual, fixed
Closed August 14, 2026
Sign in to see your limit
- Eligibility depends on residency, accreditation status and how much you have already invested this year.
- You can read everything about this offering without an account. Committing capital requires one.
Demo · viewing as
Browsing without an account. Everything is visible; nothing is purchasable until you verify who and where you are.
Or answer the questions yourselfNo money will move
No payment processor is connected. The commitment flow runs end to end, through amount, agreement, signature and receipt, and records a simulated position rather than a charge.
TRL assessment
8
Technology readiness level, 1 to 9
Confidence band 7.6 – 8.5
Molten salt thermal storage is commercially proven at concentrated solar plants and this system is complete and undergoing commissioning, which is level 8. Nothing on the nuclear side is modified, so no license amendment is required and the regulatory risk is close to nil. The commercial exposure is merchant: the revenue depends on a peak-to-off-peak price spread that competing storage will erode.
At TRL 8, the ladder permits Fixed-rate note or Municipal mini-bond and releases up to 90% of committed capital. This offering is structured as a fixed-rate note, which is consistent with that band.
Signed and published
- Reviewer
- Dr. Samuel Adeyemi
- Credential
- PhD Nuclear Engineering; ASME Section III reviewer
- Signed
- April 9, 2026
- Published
- April 10, 2026
- Methodology
- v1.4
- Model
- ci-trl-2026.06
- Generated
- Apr 4, 2026
Evidence
Every score cites the documents it was derived from, with the weight each carried. An assessment without evidence is an opinion.
| Source | Document | Date | Weight |
|---|---|---|---|
| Independent test report | Salt loop commissioning and thermal cycling Independent commissioning report Charge and discharge cycles achieved rated capacity with expected losses. | Feb 19, 2026 | 34% |
| Metered output | Commercial precedent, concentrated solar storage installations Published operating data, comparable salt storage plants Equipment class has a multi-decade commercial operating record. | Oct 30, 2025 | 26% |
| Independent test report | Host plant steam extraction impact study Independent engineering study, host operator reviewed No modification to safety-related systems; no license amendment required. | Jan 14, 2026 | 24% |
| Supplier contract | Market participation and dispatch agreement Executed agreement with the organized market operator Registered as a storage resource. No capacity payment floor. | Dec 5, 2025 | 16% |
Score history
A score changes on the day a reviewer signs a new assessment, which is why this is a step line rather than a curve.